Sometimes the on/off switch on Intermatic and other mechanical timers can get tight. I found a diagram showing neutral to A, line 1 to terminal 1 and line 2 to terminal 3. The T104RD89 timer will work with a swimming pool motor as long as the motor is 240 VAC and is under 5 HP which is what this timer is rated for. Any ideas why its doing that? Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Pool pump comes on fine with the on dog, but wont turn off. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. David, check the wiring, the power in and power out wires may be reversed. Phil. If test shows that timer is not turning ON-and-OFF, then timer is bad or trippers are worn and need replacement. Hi there, I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. Not sure if i need to check out the wiring, but it is a bit frustrating. Why is my water heater timer not working? - Quick-Advices If you dont think the mechanism is the issue, move onto the next step. If your pool pump timer isn't working, it's likely because of these explanations: Broken timer motor Power outage Circuit breaker problems Loose timer tags Disconnected wires Incorrect time of day Broken internal timer In this article, I'll discuss several reasons your pump's timer won't work. The trippers can also get damaged. Tork timer not keeping time | Mike Holt's Forum You most likely just need to now set the pins and the clock and your timer will work. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. The 2,810 sq. Pool Timer Clock Parts and Trippers You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Now remove the terminal cover on the timer. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. Thank you. My timer works good it turns on and off when I set the time. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. My intermatic pool timer will not automatically turn on. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. Proceed to step 4 to check the timer itself. The time does not advance after resetting. If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. We are on our third timer. The clock will also be missing 3-hours of time, so will need to be reset to the current time. Is there a separate switch somewhere between breaker and timer? Is it keeping time normally? It is generally not recommended to reuse a critical fastener like the rear spinal nut on your 2000 Ford Focus. "@context": "https://schema.org/",
A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? There's an issue with the wiring between the circuit breaker and the timer. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Other causes include rusted springs, insect infestation and loose timer dogs. Hi Mike, yes I sent you an email to your yahoo acct. Some of the most common issues for a pool pump timer not working are: power outage, incorrectly positioned yellow clock wheel, loose timer trippers, faulty internal timer, and a worn-out motor. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. You need extreme care in this next step. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Hi Sam, check that the dial is not warped or bent, the yellow clock dial. not sure what is the problem. Copyright 2022 In The Swim. I went to the control panel and saw that the timer needle stopped just after the start pointer. At some time the timer was disconnected and the pump wired direct to the breakers. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. $829,900. TO SET TIME-OF-DAY:Pull CLOCK-DIALoutward. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. Check that dial is not warped. It only takes a small amount of dirt to foul up gears so look carefully. I have a PF1112T. Things are working fine and all of a sudden the pool pump did not start in the morning. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. May we present Speed Tripper, the second pedal collaboration from Death By Audio and LEVITATION. Thanks in advanced. DEWENWILS Outdoor Outlet Box. Check the wiring also, looking for broken wires or loose connections, which could explain the breaker tripping as well. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. Check that the breaker is firmly pushed onto the bar, and is not loose. But no gears or any sound. Grab it, pull it towards you, move it around then place it back down. "height": "219",
If you are not sure if your timer is working or not you will first need to know if its even operational. Not two OFF trippers? However, intermittently after the ON tripper switches pump on the pump will stop. It I set the timer again it will jeep time until it gets to the next dog ear. Should You Get a Pool Pump Timer? Reset the clock on the timer to the correct time to get it back to the desired on/off times. If all looks well, and the gears are still not turning, you may need to replace the mechanism. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. My pump has a plug. My time clock has an ant infestation! My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. Any suggestions on how to troubleshoot? Learn more about pool care and repair. Turn on / off manually work fine, but The clock gears still not moving. Now Im having to turn my pool pump on and off manually. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Your timer is on a 24-hour cycle. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. Hello, yes that sounds like you need the Intermatic T104 https://www.intheswim.com/p/2-circuit-pool-timer. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Sometimes during power surges or lightning, these will be fused together and not come apart. The back of the timer dog has a tab that flips the switch, check the alignment of both, the dog may not be contacting the switch with enough surface to flip it on? Reddit - Dive into anything You can check these easily by removing them and inspecting them for damage. I have a sweeper set on auto on the second timer and it is working correctly. Or be loose and not making good contact. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). Thank you. Inspect the tripper portion, if it looks rounder or worn, replace them. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. How do you know if your pool timer is bad? A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. Pull the timer out and turn it to the correct time. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. If you loosen the hold down screw to much it could separate from the timer pin. any suggestions about how i might avoid another situation like the above would be appreciated. Black goes to _1 It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. how do I check the manual over ride switch to see if it is off? 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? Thank you for choosing Intermatic! The A terminal is not normally used, unless you have a 3 wire service. },
Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. I am using the breaker to turn on and off the pool pump. The gears in mechanical timers can get damaged. "name": "Davy Merino",
), you should be able to discern if this is the problem, which could mean a new clock. To set it, you just move the on/off "trippers" where you want them. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. the ground wire? Everythings OK now, unit works just fine. It is an ON tripper right? Reasons Why Pool Timers Stop Working 1. Voltage is 243, frequency is 60hz. Turn the metal bar until it contacts one of two plastic side tabs. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. "mainEntityOfPage": "https://blog.intheswim.com/intermatic-pool-timer-troubleshooting/",
Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Yes, seen that before! How to Install the Trippers on Intermatic Timers | eHow Could also be grit or insects inside of the gears of the clock motor. If still not working, check the wire connections and then test voltage on the clock incoming wires, outgoing wires, and then at the pump motor the problem lies, where the power dies, as they say. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. The 120V or the T101 model has 3 brass screws (terminals) underneath the plastic insulator cover. South Sea Island Accommodation: Was a good island when all the day trippers left - See 160 traveller reviews, 205 candid photos, and great deals for South Sea Island Accommodation at Tripadvisor. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement Take a good look at the position of the pins and write down the locations. I have to reset the time every day. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. If the pool timer is not keeping the correct time or losing time, there may be a simple fix. IT happens, so I ask. Grab your torch and shine it in the holes. Hi, Davy, seeing lots of complaints here. It would not reset itself and could not get power back to the timer. Wired correctly, #10 wire, nothing. Ill do the same. I have the same issue currently, and it makes no sense to me so far. Hi Davy, Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. So what would be the problem? Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. Terminals 2 and 4 are used for wires going to the load (pump). The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Is it toast ? No luck. But of the timer itself is bad you will need a licensed electrician to change the timer for you. http://waterheatertimer.org/Tork-timers-and-manuals.html #1. I realized today that my pump has been on for 11 hours, but the clock has only moved a few hours. 'Why not Toowoomba?': Tourism body says water park a missed opportunity You off course will want to adjust one time pin at a time. "@type": "ImageObject",
In most cases like this, replacing the trippers is the solution. screwfindinganame on June 18, 2013 at 11:36 pm "primaryImageOfPage": {
No broken or loose wires visible. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. With the breakers turned off, remove the mechanism from the box. },
2,767 Sq. You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. Is this a bad timer mechanism or loose wire? I need to replace a timer for my pool vacuum. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts by pool co. , so wondered about the cost. First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. How can it keep time if lever is in off position (manual lever). hi, I have a smart pump for my pool, the time clock turns on in the morning and at the same time I see that the pump has power but it doesnt turn on, I have to turn on manually, is it something that the electrician has to connect to the pump so they are synchronized? Electrical Monke Aug 25, 2021 #22 It's broken. What Causes Problems With Intermatic Timers? - Reference.com If your pool pump timer is beyond repair, call a professional to replace it. Flip it from where it is now, to the opposite side. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. I have the PF1202T timer on my pool. The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. Back when I was a young technician I was taught to always look for the easy things and use all my senses. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. Hello. Video of the Day Trippers },
Any idea what may be causing this? Commonly, many pool owners will think there pool timer is broken and not working when all they had to to is turn the circuit breaker to the on position. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. The problem lies, where the power dies, as they say, Thanks for the response. "address": "",
Hi Matthew T104 can only turn one pump on and off. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! View more property details, sales history and Zestimate data on Zillow. With the power switched off at the breaker, take out the main part of the timer and carefully inspect the gears for obstructions and missing teeth. The timer appears to be working fine (keeps time). Does this give you a better idea of the problem? Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. This will disengage the dial from the . I can manually turn it on with the lever at the bottom. My Tork TU40 pool pump timer wont turn on the pump. The red - JustAnswer March 16, 2022 by WildRiverCountry. Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) Hi Joe, could be time, for new timer. It sounds like the Line and Load wires are reversed. Inspect that the gear behind the timeclock dial, is turning (very slowly), and that nothing is caught up in the gears, like sand or a lizards tail, or bugs, etc. If you cant, is the manual switch stuck or jammed? For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. If any of these issues occur your timer will not work properly. 9 Problems with Intermatic Timers and How to Fix Them - My Perfect Pool Thanks for any help you can give. Was a good island when all the day trippers left What was the fix?? I look through the window of the panel and see the gears running well. If the pump comes on, you definitely have power to the timer. Step 3 With this model can I control both of these motors with two different on and off times. You can also apply some of the troubleshooting steps to other brand timers. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Hi Andy, when a clock is running slow, we might assume power outages, but when it runs fast, we might assume either a 60 hz (US) timeclock hooked up to 50 hz power service (Europe), or vice-versa, or a manufacturing defect in the gear tolerances could cause a synchronous motor timer to run fast. 2. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. Does this mean I need a new T104, or is there a replacement manual on/off switch? Ive got a weak pump battery so every time the mechanism shuts off it looses time. Thank you. Welcome to Pool Spa Outpost! It loses about 1.5 to 2 hours per day without any outages. I had the exact same thing happen recently. The trippers push on a tab on the on/off switch. That was probably what burned the plug. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. When I turned it back on now the pool clock goes backwards. Dont know what the issue is. Also known as an RCD (residual current device) in Australia and the UK.
Publix Employee Complaint Hotline, La Concha Renaissance San Juan Resort Day Pass, Articles P