that sounds like loose wires, or broken wires. The water does not flow when the pump is turned on. They do not seem to have enough stooch even though they are rated at 1HP like my original motor. I did notice the on/off switch was mushy moving from the on and off positions. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). You should also check for loose, crimped or broken wires or rusty terminals on the capacitor. Question, if I can determine which return pipe is broke could I just block off that return and bypass it. Could also be a loose wire connection, the power wires. Within the underground world of Japan, and the world at large, a certain man is known as the Evil Emperor. If your pump has an open bracket (where you can see the motor shaft), you can grab the shaft with your fingers or straight pliers, to break any rust. I replaced the entire pump motor and the same thing happened. I have no pressure on my filter. Any ideas or what else to check? Today two years later, same company opened pool,pump stuck and want to install another 3400vsp for $1330. If it is on low it works properly. ), maybe you can swap Assy B motor, but you say thats noisey, it could need new bearings and shaft seal. If voltage is normal, there may be a loose wire in the motor, perhaps behind the terminal board, or a bent wire that is touching some metal housing, or bent and touching another wire. If one of the keypad buttons is closed (or pressed) for more than 30 s the error code will be displayed but the control will continue to function. Pushing down on the handle briefly (pump off) can often dislodge the debris, and no gasket replacement is necessary if you are lucky. Pump flow rates are found on pump flow rate curves. the problem lies, where the power dies. In some cases, a small bit of debris (stick or sand) can become lodged between the gasket and the rotor (aka diverter or footpad) and can cause leakage. A less common cause of water out of the waste line is a broken Spring, under the handle, indicated by a floppy handle or difficulty turning the valve, I have a Hayward Super Pump it will run for about 1 to 2 hours and then it shuts off once it cools off for an hour or so I can turn it back on it will run again the water flow its good its just shuts off when it gets hot, Hi Steve; check that you have good air flow all around the pump, and above. 3. clogged pump impeller or very dirty filter. You can use a bent paperclip to ream out the orifices. The Hayward Aqua Plus Automation System should have the capability to accommodate several T-Cell sizes. I have a Hayward pro series filter and Hayward pump. If a LED is ON, check to see if the flow switch was installed correctly. We are headquartered in Valley Stream, New York, just outside of New Theory and practice | Find, read and cite all the research you need on ResearchGate We would like to show you a description here but the site wont allow us. The symptoms you describe could be shorted windings, or it could also be just a bad capacitor, or it could be a motor that is locked up, from small amounts of rust inside which is often the case for motors that have sat all winter long. Put your power leads on both sides of the transformer, should be 115V IN, and 28V OUT, (or close to those numbers). I have water coming out the side of the sand filter where u would back wash? GFCI breakers can go bad, but then again, they can be good, and this symptom could be warning you of a potentially unsafe situation. I only rotated the one piece how can the screws not go right back in? They are higher voltage or whateverbut could that be the problem? Regardless, after wiring it up (we did the hot on the bottom and neutral on the top), I put water in the basket and turned on the pump. The heat sink is a ridged metal plate beneath the drive, that relies on air flow to help remove heat from the motor. When impellers are clogged sometimes they surge. Are you using DE powder or enough DE powder? i put the hose down the skimmer outlet back to the pool to fill the pipes, still nothing. Hi Davy, Scrape out the old gasket with a sharp screwdriver and glue a new one in place with dabs of superglue gasket flat side down, ridged side up. Lighting, Learn About Is there something I forgot to do? Guess I was wrong. 908-355-7995. It could possibly be a bad cord, or a bad outlet, or loose wires on pump or outlet. It could also be the wiring from breaker to timer, or timer to pump, or just breaker to pump, if there is no timer or other switch (and if there is no other switch, the breaker is likely just worn out from overuse). I hope to hear back from you Improper voltage wiring is the usual culprit for smoking pump motors. Inground pool, 1 Bought new vac hose now own 3 If the shaft spins freely, no rust problem. Appreciate any help. Step 3: Is your cell clean? I believe you must have some type of switch, for code cant just wire it directly to the breaker. Hi I have a Hayward aquatrol above ground pool chlorine generator system. Contact a professional for further assistance. Old bronze pool pumps, like Sta-Rite and Anthony, that use Key Shaft motors with stub shafts need to be shimmed properly. Clean Gasket (no bits of debris or de powder), 2. I replaced the pump thinking it was bad. One of those areas can be sealed up to stop the leak. I turned it off overnight but still the same thing. Hi Shaun, if its not an air leak (from a loose pipe going into the pump, or loose pump lid, or low water level, or stuck skimmer weir), it then most likely is a clogged pump impeller. The pump then ran fine for about 10 minutes and then stopped working again. If the problem continues after fixing the problems above, you may have a clog in the suction side of your pump. thanks. The original pump (assy A) smells burnt. Hi Kacy, thats very odd, and likely just a coincidence that the pump works on backwash only. are red velvet ants dangerous to dogs stone county, mississippi mugshots disney half marathon 2023 crooked house (2008 trailer) "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Check all wires, to be sure that the metal ends of wires are not touching any metal ends of the motor housing, or contacting other wire metal ends. Hi Peter, I think you might be jumping the wrong terminals? 4 New pump 2 years old. For some time now I have been pushing along with my old cell (t-9 model). Could be a change in vibration, press down on the pump, to see if the tone changes. However, many inground pools do not run the pump 24/7, but operate it from 12-18 hrs daily, depending on the need, and the ability of the filtration system and sanitation efforts, etc Some small systems do need to run 24/7, but a properly sized system has a timeclock, to set it to run for around 12 hours per day (less during cool periods, more during hot spells)>. I do not see any water leaks around the pump or the filter other than a few drops under the chlorinator. What could be wring? You may need to start shopping for a new motor and shaft seal, or a whole new pump of the same size and type. Hi Rob, there could still have been some sand in the pipes yes, and thats probably the problem. My mistake was forgetting to empty pump basket. Turned it off tho clear the skimmer basket.. water level is correct. Hola tengo una caldera Hayward H400 PED2 durante el intento de encendido no enciende m caldera despus de 5 intentos me pone lF en la pantalla. Maintenance. just replaced t15 on a rev 1.45 aqua rite and the default salt reading now is 4. Whats the best and safest way to troubleshoot? If you have power there, and the motor is making no sound then I would inspect closely for a loose wire on the terminal board, or a loose switch in the back, or loose capacitor wire. We cant figure put how to get the pump going they have a circuit box outside its hooked to but it seems its not working. I rechecked the wiring, everything seems good. Check that the timer clock motor is working. Do you think its the capacitor and I can get another one from Hayward, or possibly mis-wiring? Hi there, I have a 2-speed (hi and low) Hayward pump. Troubleshooting and diagnosing their problems. Fourth, check the motor shaft to be sure that it spins easily by hand, fifth, you can check the capacitor (for capacitance), if the motor still isnt starting. If you vacuumed the floc residue into the filter, you should be able to remove most of it with a thorough backwashing of 5 minutes or so. One washer on each side of the spring, you are correct. Is this enough to cause it not to prime or is there an issue with the impeller? This error can result commonly in springtime, after the pump has sat all winter rust can develop between the stator and rotor. Sean, Hi Sean, no worries. Is this rare? When they fail, they often crack, bulge, leak or smell bad, but not always. Is this a pump problem, priming problem (filter, pipes losing water somewhere)? How do I seal it? Might wait to see if Hayward can give you an answer and probably want to contact the vendor who sold you the pump, which Hayward may require anyway? Damaged or inadequate wiring, resulting in a power drop, are likely to blame for your Hayward pool pump shutting off. Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. I opened the casing again and it had a lot of corrosion within. Specialties: Cycling, Kickboxing, The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. 2. loose pipe coming into pump, drawing air around fitting threads Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. Hi Carrie, sounds like an air leak, which is air being sucked into the pump, from somewhere in Front of the impeller, Clean the filter cartridge well, allow it to dry fully, and then replace it back in the filter tank. Can it be repaired or do we need a new pump? This quick spray of water when you shut the pump off, as you have experienced, are a useful tool in locating an air leak on a pump. Otherwise, it can be loose or corroded connections on the 3 wires that connect the motor to the drive. Hi Leah, good question, and I understand. The wiring is all new, new breakers and new sub box professionaly installed. Hi Carolyn, yes either the thermostat or other temp sensor, if present, would be responsible for that symptom. Was working fine until I backwashed and cleaned the basket by the pump. If low flow is not caused by a clogged strainer, inspect the cleaner hose for pressure loss (leaks). "mainEntityOfPage": "https://blog.intheswim.com/hayward-pool-pump-troubleshooting/",
If youre correct that theres a problem with the internal bypass, what should I do? I disconnected it and plugged the Aquatrol in alone; that worked fine. A large pair of channel type pliers can be placed on the impeller, over a cloth, and given some persuasion. Hayward pro lx 1.5hp pump turns on for 5 seconds, shuts off, then light to moderate, white electrical smoke from pump. This ONLY happens when I connect my vac hose. On the filter valve, on top of the filter tank, there are 3 Ports, labeled PUMP, RETURN and WASTE. Hi, my above ground pool pump will run when not attached to the pool and there is no water in it, but when I get it hooked up to the pool and let the hoses and pump fill, it no longer turns on. If all looks tight you may need a new Max-Flo II motor or a new Max-Flo XL pump.
1976 High School All American Football Team,
Unattached Track Meets 2022,
Articles H